NOVOTHERM™ | T1 – T2 – T3

Millenium Neotherm™ rigid insulation panels are made of expanded polystyrene [EPS] with graphite additive, available in type 1, type 2 or type 3 depending on the application and density required by your projects.

Attached files

Open or select files to share.

Description

RECOMMENDED USE

Install Novotherm™ rigid insulation board loose laid, fully adhered or mechanically fastened for a continuous thermal envelope. It is used in the design of several high performance roofing systems and walls of commercial, industrial and institutional building.

APPLICATIONS

Flat roofs, cathedral roofs, metal roofs, exterior and interior walls, foundation walls, basement walls, backfill insulation and other insulation projects.

CERTIFICATION

Warnock Hersey has certified the expanded polystyrene contained in rigid insulation boards in accordance with theCAN/ULC-S701-11 standard. The expanded polystyrene fromMillenium is listed in the CCMC Registry of Product Evaluation under CCMC 13276-L [type 1], CCMC 13271-L [type 2] and CCMC13277-L [type 3].

FEATURES AND BENEFITS

  • R-value which remains permanent with time;
  • Excellent moisture resistance within the walls;
  • Non vapour barrier – Enclosed rigid plastic cells that allows water vapour diffusion while maintaining the insulating value;
  • Versatile, lightweight, easy to transport and install;
  • 100% recyclable material;
  • Meets current building code requirements;
  • Meets CAN/ULC-S701-11 standard.

ENVIRONMENTAL DATA

Expanded polystyrene included in rigid insulation boards are composed of 98% air and 2% plastic material. They are manufactured without HCFC or HFC gases and without HBCD flame retardant.The Millenium products can contribute to LEED credits for Optimizing Energy Performance, Recycled Content, RegionalMaterials, Low-Emitting Materials [Adhesives and Sealants],Construction Waste Management and IAQ Management Plan for the Pre-Occupancy Phase.Please send us your LEED Material Declaration Formatinfo@millenium.plus.

LIMITATIONS

Expanded polystyrene is combustible. Even if expanded polystyrene contains a flame retardant, limit use of open flame or ignition sources near product. A protective barrier or thermal barrier is required as specified in the appropriate building code.Expanded polystyrene may be affected by some oil based solvents.

EXEMPTION OF LIABILITY

The information herein is based on the present state of our best scientific and practical knowledge. The user is responsible for checking the suitability of products for their intended use.Millenium technical data sheets are updated on a regular basis; it is the user’s responsibility to obtain and to confirm the most recent version. Information contained in this data sheet may change without notice.

STORAGE

Store boards in a dry location, protected from the outside elements, ultraviolet rays, open flames or other sources of ignition. Stack boards on pallets of minimum 100 mm [4”] above the ground.

INSTALLATION

Boards must be dry and in good condition before installation. To limit the color loss from UV exposure, cover the installed boards with an exterior cladding protecting from ultraviolet rays.

Technical informations

THERMAL VALUE

DimensionsThicknessType 1 Type 2 Type 3
610 mm x 2438 mm[24” x 96”] 25 mm [1”]R3.7R4.0R4.2
1219 mm x 2438 mm [48” x 96”]38 mm[1-½”]R5.6R6.0R6.3
Other dimensions and thickness available upon request. Square joints by default. 51 mm[2”]R7.4R8.0R8.4
Other dimensions and thickness available upon request. Square joints by default. 64 mm[2-½”]R9.3R10.0R10.5
Other dimensions and thickness available upon request. Square joints by default. 76 mm [3”]R11.1R12.0R12.6

Ship lap joints available on two sides for 25 mm [1”] thick panels. For panels with a minimum thickness of 38 mm [1-½”], ship lap joints available on two or four sides or EZ clip system available on two or four sides. To obtain the RSI value divide the R value by 5.678

Technical Data

Physical properties
Novotherm™Type 1Type 2Type 3
Thermal Resistance Min.RSI 0.65RSI 0.70RSI 0.74
[ASTM C518] Thickness of 25 mm [1”][R3.7][R4.0][R4.2]
MVTR Max.300 ng/Pa.s.m2200 ng/Pa.s.m2130 ng/Pa.s.m2
(ASTM E96)[5.24 US Perms][3.5 US Perms][2.27 US Perms]
Compressive Strength Min.70 kPa110 kPa140 kPa
[ASTM D1621] 10% Deformation[10 PSI][16 PSI][20 PSI]
Flexural Strength Min.170 kPa240 kPa300 kPa
[ASTM C203][25 PSI][35 PSI][44 PSI]
Water Absorption Max.
[ASTM D2842] Volume6%4%2%
Dimensional Stability Max.
[ASTM D2126] Linear Variation1.5%1.5%1.5%
Limiting Oxygen Index Min.
[ASTM D2863]24%24%24%
Density Min.16 Kg/m320 Kg/m325 Kg/m3
[ASTM C303][1.00 lbs/ft3][1.25 lbs/ft3][1.5 lbs/ft3]
Flame Spread Rating
[CAN/ULC S102.2]145145145

More informations

Contact Us