NOVO-ISO BZO
Attached files
Open or select files to share.
Description
RECOMMENDED USE
Install tapered rigid insulation panels to ensure a positive slope to drain, scupper and gutter. Ideal for roofing applications that use typical roofing materials, such as Built-Up Roofing, EPDM, TPO, PVC and modified bitumen.
APPLICATIONS
Slope system for roof with drain, single slope, perimeter slope, counter-slope, cricket, deck grading and other possibilities available on request.
INSTALLATION
On wood or steel decks, the panels can be mechanically fastened using screws and insulation plates. On all types of decks, the panels can be adhered with hot bitumen or a two-component polyurethane adhesive.
It is strongly recommended to follow the installation plan that is provided upon delivery. This plan also specifies the first panel to be installed. It is important to follow this recommendation which takes into account the cuts that will have to be made on site.
Technical Informations
Panel size
| 1 219 mm x 1 219 mm | [48” x 48”] |
Most Common Slopes
| 1% | 2% | 4% |
The percentage of slope is established according to your needs and the panels are custom-cut according to a predetermined pattern made by Millenium which ensures water flowing to desired locations.
Slope insulation panel boards have square joints on all 4 sides. An installation layout is provided by Millenium to ensure optimal drainage and quality of installation on the job site.
Technical Data
Physical Properties
| Characteristics | Units | Meets or exceeds | Specification | Test Method | Standard Limits |
| Long Term TR RSI (R) (Btu•hr•pi2•°F) | 25 mm RSI (R) 50 mm RSI (R) 75 mm RSI (R) | 0,99 (5,7) 2.01 (11,4) 3.06 (17,4) | CAN/ULC S704 | CAN/ULC S770 | --- |
| Compressive Strength | kPa (psi) | 138 (20) ou 172 (25) | CAN/ULC S704 | ASTM D1621 | N/A |
| Dimensional Stability (Linear) | % | < 0,5 | CAN/ULC S704 | ASTM D2126 | Max: ± 2 |
| Water Absorption | %Vol. | Yes | CAN/ULC S704 | ASTM C2842 | Max: 3,5 |