Novotherm™ – type 1 et 2

Novotherm™ – Type 1 and 2

Rigid insulation board for flat roofs, walls and foundations. Millenium rigid insulation boards are made of type 1 or type 2 expanded polystyrene [EPS], depending on the application and the density required by your projects.

Contact an Expert

Documents

Select the documents you want to download.

Recommended use and applications

Recommended use Install Novotherm™ rigid insulation boards loose laid, adhered or mechanically fastened to obtain a continuous thermal envelope. It is used in the design of several high-performance roofing and wall systems on many commercial, industrial and institutional buildings. Applications Flat roofs, cathedral roofs, metal roofs, exterior and interior walls, foundation walls, basement walls, backfill insulation and any other insulation project.

Thermal value

ThicknessType 1Type 2
25 mm [1”]R3.7R4.0
38 mm [1-½”]R5.6R6.0
51 mm [2”]R7.4R8.0
64 mm [2-½”]R9.3R10.0
76 mm [3”]R11.1R12.0
Dimensions: 610 mm x 2,438 mm [24” x 96”]; 1,219 mm x 2,438 mm [48” x 96”]. Other dimensions and thicknesses available upon request. Square joints by default. Ship lap joints available on two sides for 25 mm [1”] thick panels. For panels with a minimum thickness of 38 mm [1-½”], ship lap joints available on two or four sides or EZ clip system available on two or four sides. To obtain the RSI value, divide the R value by 5.678.

Features and benefits

  • R-value that remains permanent over time;
  • Excellent moisture resistance within a wall assembly;
  • Non vapour barrier: closed rigid plastic cells allow water vapour diffusion while maintaining the insulating value;
  • Versatile, lightweight, easy to transport and install;
  • 100% recyclable material;
  • Meets the requirements of current building codes;
  • Complies with the CAN/ULC-S701-11 standard.

Technical data

Physical propertiesType 1Type 2
Min. thermal resistance [ASTM C518], 25 mm [1”] thicknessRSI 0.65 [R3.7]RSI 0.70 [R4.0]
Max. water vapour permeance [ASTM E96]300 ng/Pa.s.m² [5.24 US Perms]200 ng/Pa.s.m² [3.5 US Perms]
Compressive strength [ASTM D1621], 1½” (38 mm) thickness±93 kPa [±13 PSI]±122 kPa [±18 PSI]
Min. flexural strength [ASTM C203]170 kPa [25 PSI]240 kPa [35 PSI]
Max. water absorption [ASTM D2842], volume6%4%
Max. dimensional stability [ASTM D2126], linear variation1.5%1.5%
Min. limiting oxygen index [ASTM D2863]24%24%
Min. density [ASTM C303]16 kg/m³ [1.00 lb/ft³]20 kg/m³ [1.25 lb/ft³]
Flame spread rating [CAN/ULC S102.2]145145

Certification and environment

Certification The expanded polystyrene in the rigid insulation boards has been evaluated by an external laboratory and complies with the CAN/ULC-S701-11 standard, type 1 and type 2. Millenium expanded polystyrene is listed in the Canadian Construction Materials Centre (CCMC) Registry of Product Evaluations under several technical evaluations. Environmental data The expanded polystyrene in the rigid insulation boards is composed of 98% air and 2% plastic material. Millenium products can contribute to LEED credits for Optimizing Energy Performance, Recycled Content, Regional Materials, Low-Emitting Materials [Adhesives and Sealants], Construction Waste Management and IAQ Management Plan for the Pre-Occupancy Phase. It contains no HCFC, HFC or flame retardant containing HBCD. Limitations Expanded polystyrene is combustible. Even if expanded polystyrene contains a flame retardant, limit use of open flame or ignition sources near product. A protective barrier or thermal barrier is required as specified in the appropriate building code. Expanded polystyrene may be affected by some oil based solvents. Storage Store boards in a dry location, protected from the outside elements, ultraviolet rays, open flames or other sources of ignition. Stack boards on pallets of minimum 100 mm [4”] above the ground.