Neotherm™ PSE – type 1, 2, 3

Neotherm™ EPS – Type 1, 2, 3

Rigid insulation board for flat roofs, walls and foundations. The rigid insulation board from Millenium is composed of type 1, type 2 or type 3 expanded polystyrene [EPS] rigid foam insulation.

Contact an Expert

Documents

Select the documents you want to download.

Recommended use and applications

Recommended use Install Neotherm™ EPS rigid insulation board loose laid, fully adhered or mechanically fastened for a continuous thermal envelope. It is used in the design of several high-performance roofing systems and walls of commercial, industrial and institutional buildings. Applications Flat roofs, cathedral roofs, metal roofs, exterior and interior walls, foundation walls, basement walls, backfill insulation and other insulation projects.

Thermal value

ThicknessType 1Type 2Type 3
25 mm [1”]R4.5R4.6R4.6
38 mm [1-½”]R6.75R6.9R6.9
51 mm [2”]R9.0R9.2R9.2
64 mm [2-½”]R11.25R11.5R11.5
76 mm [3”]R13.5R13.8R13.8
Dimensions: 610 mm x 2,438 mm [24” x 96”]; 1,219 mm x 2,438 mm [48” x 96”]. Other dimensions and thicknesses available upon request. Square joints by default. Ship lap joints available on two sides for 25 mm [1”] thick panels. For panels with a minimum thickness of 38 mm [1-½”], ship lap joints available on two or four sides or EZ clip system available on two or four sides.

Features and benefits

  • R-value which remains permanent with time;
  • Excellent R-value/cost ratio;
  • More than 4 times more stable dimensionally than the requirements of the CAN/ULC-S701-11 standard;
  • Excellent moisture resistance within the walls;
  • Non vapour barrier - Enclosed rigid plastic cells that allow water vapour diffusion while maintaining the insulating value;
  • Versatile, lightweight, easy to transport and install;
  • 100% recyclable material.

Technical data

Physical propertiesType 1Type 2Type 3
Min. thermal resistance [ASTM C518], 25 mm [1”] thicknessRSI 0.65RSI 0.70RSI 0.74
Max. water vapour permeance [ASTM E96]300 ng/Pa.s.m²200 ng/Pa.s.m²130 ng/Pa.s.m²
Min. compressive strength [ASTM D1621], 10% deformation70 kPa [10 PSI]110 kPa [16 PSI]140 kPa [20 PSI]
Min. flexural strength [ASTM C203]170 kPa [25 PSI]240 kPa [35 PSI]300 kPa [44 PSI]
Max. water absorption [ASTM D2842], volume6%4%2%
Max. dimensional stability [ASTM D2126], linear variation1.5%1.5%1.5%
Min. limiting oxygen index [ASTM D2863]24%24%24%
Min. density [ASTM C303]16 kg/m³ [1.00 lb/ft³]20 kg/m³ [1.25 lb/ft³]25 kg/m³ [1.5 lb/ft³]

Certification and environment

Certification Warnock Hersey has certified the expanded polystyrene contained in rigid insulation boards in accordance with the CAN/ULC-S701-11 standard. The expanded polystyrene from Millenium is listed in the CCMC Registry of Product Evaluation under CCMC 13276-L. Environmental data The expanded polystyrene in the rigid insulation boards is composed of 98% air and 2% plastic material. Millenium products can contribute to LEED credits for Optimizing Energy Performance, Recycled Content, Regional Materials, Low-Emitting Materials [Adhesives and Sealants], Construction Waste Management and IAQ Management Plan for the Pre-Occupancy Phase. They are manufactured without HCFC or HFC gases. Limitations Expanded polystyrene is combustible. Even if expanded polystyrene contains a flame retardant, limit use of open flame or ignition sources near product. A protective barrier or thermal barrier is required as specified in the appropriate building code. Expanded polystyrene may be affected by some oil based solvents. Storage Store boards in a dry location, protected from the outside elements, ultraviolet rays, open flames or other sources of ignition. Stack boards on pallets of minimum 100 mm [4”] above the ground.