Novotherm™ FIT – remplissage de cannelures

Novotherm™ FIT – Flute Fillers

Rigid insulation custom cut and profiled by Millenium, in type 1, type 2 or type 3 expanded polystyrene [EPS], to fill the flutes of a metal deck, wall or metal roof.

Contact an Expert

Documents

Select the documents you want to download.

Recommended use and applications

Recommended use Install Novotherm™ Fit to fill the flutes of a metal deck, wall or metal roof. By adding a new support board over Novotherm™ Fit, you get the best solution for building a new roofing assembly on a low-slope metal roof. Applications Metal roof filling, metal deck filling, insulated wall panel design, moulding for acrylic cladding and any other project requiring custom profiled insulation.

Benefits

  • Permanent dimensional stability over time;
  • Excellent moisture resistance within wall and roof assemblies;
  • Non vapour barrier: closed rigid plastic cells allow water vapour diffusion while maintaining the insulating value;
  • Versatile, lightweight, easy to transport and install;
  • 100% recyclable material;
  • Meets the requirements of current building codes;
  • Complies with the CAN/ULC-S701-11 standard.

Technical data

Physical propertiesType 1Type 2Type 3
Min. thermal resistance [ASTM C518], 25 mm [1”] thicknessRSI 0.65RSI 0.70RSI 0.74
Max. water vapour permeance [ASTM E96]300 ng/Pa.s.m²200 ng/Pa.s.m²130 ng/Pa.s.m²
Min. compressive strength [ASTM D1621], 10% deformation70 kPa [10 PSI]110 kPa [16 PSI]140 kPa [20 PSI]
Min. flexural strength [ASTM C203]170 kPa [25 PSI]240 kPa [35 PSI]300 kPa [44 PSI]
Max. water absorption [ASTM D2842], volume6%4%2%
Max. dimensional stability [ASTM D2126], linear variation1.5%1.5%1.5%
Min. limiting oxygen index [ASTM D2863]24%24%24%
Min. density [ASTM C303]16 kg/m³ [1.00 lb/ft³]20 kg/m³ [1.25 lb/ft³]25 kg/m³ [1.5 lb/ft³]
Flame spread rating [CAN/ULC S102.2]145145145

Certification and environment

Certification The expanded polystyrene in the rigid insulation boards has been evaluated by Warnock Hersey and complies with the CAN/ULC-S701-11 standard. Millenium expanded polystyrene is listed in the Canadian Construction Materials Centre (CCMC) Registry of Product Evaluations under CCMC 13276-L [type 1], CCMC 13271-L [type 2] and CCMC 13277-L [type 3]. Environmental data The expanded polystyrene in the rigid insulation boards is composed of 98% air and 2% plastic material. Millenium products can contribute to LEED credits for Optimizing Energy Performance, Recycled Content, Regional Materials, Low-Emitting Materials [Adhesives and Sealants], Construction Waste Management and IAQ Management Plan for the Pre-Occupancy Phase. It contains no HCFC, HFC or flame retardant containing HBCD.

Installation and storage

Installation Boards must be dry and in good condition before installation. To limit discoloration from UV exposure, cover the installed boards with an exterior cladding that protects from UV rays. Limitations Expanded polystyrene is combustible. Even if expanded polystyrene contains a flame retardant, limit use of open flame or ignition sources near product. A protective barrier or thermal barrier is required as specified in the appropriate building code. Expanded polystyrene may be affected by some oil based solvents. Storage Store boards in a dry location, protected from the outside elements, ultraviolet rays, open flames or other sources of ignition. Stack boards on pallets of minimum 100 mm [4”] above the ground.