Novotherm™ BZO – isolant de pente

Novotherm™ BZO – Tapered Insulation

Tapered rigid insulation board for roofing, custom-made by Millenium to the specified dimensions and slope, in type 1, 2 or 3 expanded polystyrene [EPS].

Contact an Expert

Documents

Select the documents you want to download.

Recommended use and applications

Recommended use Install tapered insulation boards to provide a positive slope and direct rainwater toward drains, scuppers or gutters. Ideal for applications with traditional roof covering materials such as built-up, EPDM, TPO, PVC and modified bitumen roofing systems. Applications Slope system with drain, single slope, perimeter slope, counter-slope, saddles, crickets, deck levelling, fill and other options available upon request.

Dimensions and slopes

Board dimensions 1,219 mm x 1,219 mm [48” x 48”] Common slopes 0.5% • 1% • 1.5% • 2% • 3% • 4% The slope percentage is set according to your needs and the boards are custom cut according to a layout prepared by Millenium, ensuring water drains toward the desired locations. Tapered insulation boards have square joints on all 4 sides. A shop drawing is provided by Millenium to ensure quality installation on site and optimal drainage.

Benefits and warranty

  • Provides a positive slope toward drains while keeping the structural and economic advantages of a flat deck;
  • Adapts to all deck types;
  • R-value that remains permanent over time;
  • Thicknesses and slopes as specified;
  • 100% recyclable material;
  • Low water absorption: absorbs 50% to 75% less water depending on the type of EPS used, according to the requirements of the CAN/ULC-S701-11 standard;
  • Complies with the CAN/ULC-S701-11 standard.
Warranty The thermal resistance of the product is 100% guaranteed at no cost for a period of at least 35 years.

Technical data

Physical propertiesType 1Type 2Type 3
Min. thermal resistance [ASTM C518], 25 mm [1”] thicknessRSI 0.65RSI 0.70RSI 0.74
Max. water vapour permeance [ASTM E96]300 ng/Pa.s.m²200 ng/Pa.s.m²130 ng/Pa.s.m²
Min. compressive strength [ASTM D1621], 10% deformation70 kPa [10 PSI]110 kPa [16 PSI]140 kPa [20 PSI]
Min. flexural strength [ASTM C203]170 kPa [25 PSI]240 kPa [35 PSI]300 kPa [44 PSI]
Max. water absorption [ASTM D2842], volume6%4%2%
Max. dimensional stability [ASTM D2126], linear variation1.5%1.5%1.5%
Min. limiting oxygen index [ASTM D2863]24%24%24%
Min. density [ASTM C303]16 kg/m³ [1.00 lb/ft³]20 kg/m³ [1.25 lb/ft³]25 kg/m³ [1.5 lb/ft³]
Flame spread rating [CAN/ULC S102.2]145145145

Certification and environment

Certification The expanded polystyrene in the rigid insulation boards has been evaluated by Warnock Hersey and complies with the CAN/ULC-S701-11 standard. Environmental data The expanded polystyrene in the rigid insulation boards is composed of 98% air and 2% plastic material. Millenium products can contribute to LEED credits for Optimizing Energy Performance, Recycled Content, Regional Materials, Low-Emitting Materials [Adhesives and Sealants], Construction Waste Management and IAQ Management Plan for the Pre-Occupancy Phase. It is free of HCFC, HFC and flame retardant containing HBCD. Installation Boards must be dry and in good condition before installation. To limit discoloration from UV exposure, cover the installed boards with a UV-protective membrane. Limitations Expanded polystyrene is combustible. Even if expanded polystyrene contains a flame retardant, limit use of open flame or ignition sources near product. A protective barrier or thermal barrier is required as specified in the appropriate building code. Expanded polystyrene may be affected by some oil based solvents. The maximum continuous use temperature of expanded polystyrene is 75 °C [167 °F]. Constant exposure to temperatures above 75 °C [167 °F] will cause the product to shrink and deform. Storage Store boards in a dry location, protected from the outside elements, ultraviolet rays, open flames or other sources of ignition. Stack boards on pallets of minimum 100 mm [4”] above the ground.